When considering the cooling of electronic
components we can simplify the objectives as
follows;
• Reduce the overall electronic function
cost,
• Reduce the application’s required
component rating,
• Increase the commutated power,
• Improved long term reliability.
To illustrate this, we consider the following
example. An Electronic surface mount component
is placed on the cooling device, as seen in
previous schematic. If we define a coefficient
of exchange, Heq, and a thermal resistance of
the cooling device, Rhs as follows:
|
Heq =
|
P
|
(W/m2 °C)
|
Rhs = 1/Heq (°Cm2/W) |
|
----------------
|
|
S(Tp-Ts)
|
To summarize: The higher the Heq the more efficient
the cooling device. A higher Heq can bring success
in reaching the objectives.
Table on the right shows a relative comparison
of the HS Marston Solutions applying the Heq
values. Also see each specific data sheet which
indicates relative Heq characteristics.